lab chart pro 7 software Search Results


90
OriginLab corp analysis software origin pro 7.5
Analysis Software Origin Pro 7.5, supplied by OriginLab corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/analysis software origin pro 7.5/product/OriginLab corp
Average 90 stars, based on 1 article reviews
analysis software origin pro 7.5 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
OriginLab corp origin pro 7.5 sro software
Origin Pro 7.5 Sro Software, supplied by OriginLab corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/origin pro 7.5 sro software/product/OriginLab corp
Average 90 stars, based on 1 article reviews
origin pro 7.5 sro software - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
OriginLab corp origin pro 7 data analysis software
Origin Pro 7 Data Analysis Software, supplied by OriginLab corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/origin pro 7 data analysis software/product/OriginLab corp
Average 90 stars, based on 1 article reviews
origin pro 7 data analysis software - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

98
ADInstruments single lead electrocardiography
Single Lead Electrocardiography, supplied by ADInstruments, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/single lead electrocardiography/product/ADInstruments
Average 98 stars, based on 1 article reviews
single lead electrocardiography - by Bioz Stars, 2026-06
98/100 stars
  Buy from Supplier

93
ADInstruments module
Module, supplied by ADInstruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/module/product/ADInstruments
Average 93 stars, based on 1 article reviews
module - by Bioz Stars, 2026-06
93/100 stars
  Buy from Supplier

90
QImaging software q-capture pro 7
Software Q Capture Pro 7, supplied by QImaging, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/software q-capture pro 7/product/QImaging
Average 90 stars, based on 1 article reviews
software q-capture pro 7 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
SoftMax Inc softmax pro 7
A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal increase and decrease of 485 and 535 nm H188 relative fluorescence unit (RFU) emission intensity in response to application of 300 pM glucagon to HEK293-hGCG-R-H188 c10 cell suspensions. Administration of the test substance is indicated by the vertical arrow, here and in subsequent figures. B. Determination of the single well percent change of H188 485/535 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 2A. An increase of the 485/535 nm FRET ratio signifies an increase of [cAMP]. A value of 0 is obtained after baseline subtraction of the FRET ratio at time point 0. A value of 70 corresponds to a 70% increase of FRET ratio relative to baseline. C. Glucagon produced a time-dependent and dose-dependent increase of the 485/535 nm H188 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 12 wells. D. Non-linear regression analysis of the data illustrated in panel 2C demonstrated that the EC50 for glucagon action in this cell line was 8.1 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.
Softmax Pro 7, supplied by SoftMax Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/softmax pro 7/product/SoftMax Inc
Average 90 stars, based on 1 article reviews
softmax pro 7 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
wavemetrics inc igor pro 7
A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal increase and decrease of 485 and 535 nm H188 relative fluorescence unit (RFU) emission intensity in response to application of 300 pM glucagon to HEK293-hGCG-R-H188 c10 cell suspensions. Administration of the test substance is indicated by the vertical arrow, here and in subsequent figures. B. Determination of the single well percent change of H188 485/535 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 2A. An increase of the 485/535 nm FRET ratio signifies an increase of [cAMP]. A value of 0 is obtained after baseline subtraction of the FRET ratio at time point 0. A value of 70 corresponds to a 70% increase of FRET ratio relative to baseline. C. Glucagon produced a time-dependent and dose-dependent increase of the 485/535 nm H188 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 12 wells. D. Non-linear regression analysis of the data illustrated in panel 2C demonstrated that the EC50 for glucagon action in this cell line was 8.1 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.
Igor Pro 7, supplied by wavemetrics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/igor pro 7/product/wavemetrics inc
Average 90 stars, based on 1 article reviews
igor pro 7 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
MDS Analytical Technologies Inc axon genepix pro 7
A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal increase and decrease of 485 and 535 nm H188 relative fluorescence unit (RFU) emission intensity in response to application of 300 pM glucagon to HEK293-hGCG-R-H188 c10 cell suspensions. Administration of the test substance is indicated by the vertical arrow, here and in subsequent figures. B. Determination of the single well percent change of H188 485/535 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 2A. An increase of the 485/535 nm FRET ratio signifies an increase of [cAMP]. A value of 0 is obtained after baseline subtraction of the FRET ratio at time point 0. A value of 70 corresponds to a 70% increase of FRET ratio relative to baseline. C. Glucagon produced a time-dependent and dose-dependent increase of the 485/535 nm H188 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 12 wells. D. Non-linear regression analysis of the data illustrated in panel 2C demonstrated that the EC50 for glucagon action in this cell line was 8.1 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.
Axon Genepix Pro 7, supplied by MDS Analytical Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/axon genepix pro 7/product/MDS Analytical Technologies Inc
Average 90 stars, based on 1 article reviews
axon genepix pro 7 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Reliasoft Corporation alta pro 7
A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal increase and decrease of 485 and 535 nm H188 relative fluorescence unit (RFU) emission intensity in response to application of 300 pM glucagon to HEK293-hGCG-R-H188 c10 cell suspensions. Administration of the test substance is indicated by the vertical arrow, here and in subsequent figures. B. Determination of the single well percent change of H188 485/535 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 2A. An increase of the 485/535 nm FRET ratio signifies an increase of [cAMP]. A value of 0 is obtained after baseline subtraction of the FRET ratio at time point 0. A value of 70 corresponds to a 70% increase of FRET ratio relative to baseline. C. Glucagon produced a time-dependent and dose-dependent increase of the 485/535 nm H188 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 12 wells. D. Non-linear regression analysis of the data illustrated in panel 2C demonstrated that the EC50 for glucagon action in this cell line was 8.1 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.
Alta Pro 7, supplied by Reliasoft Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/alta pro 7/product/Reliasoft Corporation
Average 90 stars, based on 1 article reviews
alta pro 7 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
wavemetrics inc igor pro
A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal increase and decrease of 485 and 535 nm H188 relative fluorescence unit (RFU) emission intensity in response to application of 300 pM glucagon to HEK293-hGCG-R-H188 c10 cell suspensions. Administration of the test substance is indicated by the vertical arrow, here and in subsequent figures. B. Determination of the single well percent change of H188 485/535 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 2A. An increase of the 485/535 nm FRET ratio signifies an increase of [cAMP]. A value of 0 is obtained after baseline subtraction of the FRET ratio at time point 0. A value of 70 corresponds to a 70% increase of FRET ratio relative to baseline. C. Glucagon produced a time-dependent and dose-dependent increase of the 485/535 nm H188 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 12 wells. D. Non-linear regression analysis of the data illustrated in panel 2C demonstrated that the EC50 for glucagon action in this cell line was 8.1 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.
Igor Pro, supplied by wavemetrics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/igor pro/product/wavemetrics inc
Average 90 stars, based on 1 article reviews
igor pro - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
QImaging qimaging pro 7.0
A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal increase and decrease of 485 and 535 nm H188 relative fluorescence unit (RFU) emission intensity in response to application of 300 pM glucagon to HEK293-hGCG-R-H188 c10 cell suspensions. Administration of the test substance is indicated by the vertical arrow, here and in subsequent figures. B. Determination of the single well percent change of H188 485/535 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 2A. An increase of the 485/535 nm FRET ratio signifies an increase of [cAMP]. A value of 0 is obtained after baseline subtraction of the FRET ratio at time point 0. A value of 70 corresponds to a 70% increase of FRET ratio relative to baseline. C. Glucagon produced a time-dependent and dose-dependent increase of the 485/535 nm H188 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 12 wells. D. Non-linear regression analysis of the data illustrated in panel 2C demonstrated that the EC50 for glucagon action in this cell line was 8.1 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.
Qimaging Pro 7.0, supplied by QImaging, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/qimaging pro 7.0/product/QImaging
Average 90 stars, based on 1 article reviews
qimaging pro 7.0 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal increase and decrease of 485 and 535 nm H188 relative fluorescence unit (RFU) emission intensity in response to application of 300 pM glucagon to HEK293-hGCG-R-H188 c10 cell suspensions. Administration of the test substance is indicated by the vertical arrow, here and in subsequent figures. B. Determination of the single well percent change of H188 485/535 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 2A. An increase of the 485/535 nm FRET ratio signifies an increase of [cAMP]. A value of 0 is obtained after baseline subtraction of the FRET ratio at time point 0. A value of 70 corresponds to a 70% increase of FRET ratio relative to baseline. C. Glucagon produced a time-dependent and dose-dependent increase of the 485/535 nm H188 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 12 wells. D. Non-linear regression analysis of the data illustrated in panel 2C demonstrated that the EC50 for glucagon action in this cell line was 8.1 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.

Journal: Bio-protocol

Article Title: FRET Reporter Assays for cAMP and Calcium in a 96-well Format Using Genetically Encoded Biosensors Expressed in Living Cells

doi: 10.21769/bioprotoc.3641

Figure Lengend Snippet: A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal increase and decrease of 485 and 535 nm H188 relative fluorescence unit (RFU) emission intensity in response to application of 300 pM glucagon to HEK293-hGCG-R-H188 c10 cell suspensions. Administration of the test substance is indicated by the vertical arrow, here and in subsequent figures. B. Determination of the single well percent change of H188 485/535 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 2A. An increase of the 485/535 nm FRET ratio signifies an increase of [cAMP]. A value of 0 is obtained after baseline subtraction of the FRET ratio at time point 0. A value of 70 corresponds to a 70% increase of FRET ratio relative to baseline. C. Glucagon produced a time-dependent and dose-dependent increase of the 485/535 nm H188 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 12 wells. D. Non-linear regression analysis of the data illustrated in panel 2C demonstrated that the EC50 for glucagon action in this cell line was 8.1 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.

Article Snippet: list-behavior=enumerated prefix-word= mark-type=upper-alpha max-label-size=0 Instrument preparation: see Video 1 FlexStation 3 and SoftMax Pro 7 Preparation for details list-behavior=enumerated prefix-word= mark-type=decimal max-label-size=0 Turn on FlexStation 3.

Techniques: Fluorescence, Produced, Software

A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal decrease and increase of 485 and 535 nm YC3.60 relative fluorescence unit (RFU) emission intensity in response to application of CCK2 receptor agonist DG2 (300 nM) to suspensions of HEK293-hCCK2R c29 cells adenovirally transduced with YC3.60. B. Determination of the single well percent change of YC3.60 535/485 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 3A. An increase of the 535/485 nm FRET ratio signifies an increase of [Ca2+]i. C. DG2 produced a time-dependent and dose-dependent increase of the 535/485 nm YC3.60 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 6 wells. D. Non-linear regression analysis of the data illustrated in panel 3C demonstrated that the EC50 for DG2 action in this cell line was 604 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.

Journal: Bio-protocol

Article Title: FRET Reporter Assays for cAMP and Calcium in a 96-well Format Using Genetically Encoded Biosensors Expressed in Living Cells

doi: 10.21769/bioprotoc.3641

Figure Lengend Snippet: A. Raw data obtained from a single well on the reading plate illustrates the time-dependent reciprocal decrease and increase of 485 and 535 nm YC3.60 relative fluorescence unit (RFU) emission intensity in response to application of CCK2 receptor agonist DG2 (300 nM) to suspensions of HEK293-hCCK2R c29 cells adenovirally transduced with YC3.60. B. Determination of the single well percent change of YC3.60 535/485 nm emission ratio (% ΔFRET) calculated using the single well raw data illustrated in panel 3A. An increase of the 535/485 nm FRET ratio signifies an increase of [Ca2+]i. C. DG2 produced a time-dependent and dose-dependent increase of the 535/485 nm YC3.60 FRET ratio. Data for each time point is the mean % ΔFRET ± S.D. for n = 6 wells. D. Non-linear regression analysis of the data illustrated in panel 3C demonstrated that the EC50 for DG2 action in this cell line was 604 pM. Non-linear regression analysis was performed with Origin 8 software using the highest ΔFRET values for each data point. Non-linear reduction can also be performed with GraphPad Prism 8. For instruction in how to obtain values for time-dependent, dose-dependent and non-linear reduction with SoftMax Pro 7.1 see Video 2.

Article Snippet: list-behavior=enumerated prefix-word= mark-type=upper-alpha max-label-size=0 Instrument preparation: see Video 1 FlexStation 3 and SoftMax Pro 7 Preparation for details list-behavior=enumerated prefix-word= mark-type=decimal max-label-size=0 Turn on FlexStation 3.

Techniques: Fluorescence, Transduction, Produced, Software